Hydro Tower without regulation

HWK 332
HWK 332

Order reference: HWK 332

The Hydro Tower enables the fast and simple connection of a heat pump for heating purposes to a heating system with an unmixed heating circuit. The following components are mounted in a space-saving way and wired ready to use.

  • Buffer tank (100 l) with installation option for an additional immersion heater (up to CTHK 634)
  • Domestic hot water cylinder 300 l with 3.2 m² tube heat exchanger and 1.5 kW flange heater for thermal disinfection
  • Electronically regulated circulating pump (energy efficiency class A) wired ready to use for unmixed heating circuits (consumer circuit)
  • Unregulated auxiliary circulating pump for generator circuit and domestic hot water loading pump
  • Switchable pipe heater (2/4/6 kW) for supplementary heating
  • Safety valve incl. connection for an expansion vessel
  • The hydraulic isolation of the generator circuit and the consumer circuit is carried out via two differential pressureless manifolds (bypass pipes), which are each fitted with a check valve.
To reduce the run times, the unregulated auxiliary circulating pump in the generator circuit is only operated when the compressor is running and when there is a risk of frost. The uniform flow through the buffer tank connected in series extends the runtimes of the compressor and ensures the required heating water flow rate in all operating modes. Access for service work from the front, no minimum clearances required on the sides. Left and right-side wall installation is possible.

  • Dimensions (Width x Height x Depth): 710 x 1890 x 950 mm
  • Diameter: 710 mm
  • Weight: 210 kg
  • Connection voltage: 3/N/PE ~400 V, 50 Hz

» Instruction for use

 

LA 9TU heat pump and Hydro Tower

HPL ..TUW
HPL ..TUW

Order reference: HPL 9TUW

The Hydro Tower with integrated WPM EconPlus regulation enables the fast and simple connection of a high-efficiency air-to-water heat pump installed outdoors to a heating system with an unmixed heating circuit. The following components are mounted in a space-saving way and wired ready to use.

  • Switchable pipe heater (2/4/6 kW) for supplementary heating
  • Buffer tank (100 l) with installation option for an additional immersion heater (up to CTHK 634)
  • Domestic hot water cylinder 300 l with 3.2 m² tube heat exchanger and 1.5 kW flange heater for thermal disinfection
  • Electronically regulated circulating pump (energy efficiency class A) wired ready to use for unmixed heating circuits (consumer circuit)
  • Unregulated auxiliary circulating pump for generator circuit and domestic hot water loading pump
  • The hydraulic isolation of the generator circuit and the consumer circuit is carried out via two differential pressureless manifolds (bypass pipes), which are each fitted with a check valve.
To reduce the run times, the unregulated auxiliary circulating pump in the generator circuit is only operated when the compressor is running and when there is a risk of frost. The uniform flow through the buffer tank connected in series extends the runtimes of the compressor and ensures the required heating water flow rate in all operating modes. Electrical connection cable EVL ..U between heat pump and heat pump manager must be ordered separately.

  • Weight: 418 kg
  • Connection voltage: 3/N/PE ~400 V, 50 Hz

» Instruction for use

» Instruction for use

 

LA 12TU heat pump and Hydro Tower

HPL ..TUW
HPL ..TUW

Order reference: HPL 12TUW

The Hydro Tower with integrated WPM EconPlus regulation enables the fast and simple connection of a high-efficiency air-to-water heat pump installed outdoors to a heating system with an unmixed heating circuit. The following components are mounted in a space-saving way and wired ready to use.

  • Switchable pipe heater (2/4/6 kW) for supplementary heating
  • Buffer tank (100 l) with installation option for an additional immersion heater (up to CTHK 634)
  • Domestic hot water cylinder 300 l with 3.2 m² tube heat exchanger and 1.5 kW flange heater for thermal disinfection
  • Electronically regulated circulating pump (energy efficiency class A) wired ready to use for unmixed heating circuits (consumer circuit)
  • Unregulated auxiliary circulating pump for generator circuit and domestic hot water loading pump
  • The hydraulic isolation of the generator circuit and the consumer circuit is carried out via two differential pressureless manifolds (bypass pipes), which are each fitted with a check valve.
To reduce the run times, the unregulated auxiliary circulating pump in the generator circuit is only operated when the compressor is running and when there is a risk of frost. The uniform flow through the buffer tank connected in series extends the runtimes of the compressor and ensures the required heating water flow rate in all operating modes. Electrical connection cable EVL ..U between heat pump and heat pump manager must be ordered separately.

  • Weight: 490 kg
  • Connection voltage: 3/N/PE ~400 V, 50 Hz

» Instruction for use

» Instruction for use

 

LA 17TU heat pump and Hydro Tower

HPL ..TUW
HPL ..TUW

Order reference: HPL 17TUW

The Hydro Tower with integrated WPM EconPlus regulation enables the fast and simple connection of a high-efficiency air-to-water heat pump installed outdoors to a heating system with an unmixed heating circuit. The following components are mounted in a space-saving way and wired ready to use.

  • Switchable pipe heater (2/4/6 kW) for supplementary heating
  • Buffer tank (100 l) with installation option for an additional immersion heater (up to CTHK 634)
  • Domestic hot water cylinder 300 l with 3.2 m² tube heat exchanger and 1.5 kW flange heater for thermal disinfection
  • Electronically regulated circulating pump (energy efficiency class A) wired ready to use for unmixed heating circuits (consumer circuit)
  • Unregulated auxiliary circulating pump for generator circuit and domestic hot water loading pump
  • The hydraulic isolation of the generator circuit and the consumer circuit is carried out via two differential pressureless manifolds (bypass pipes), which are each fitted with a check valve.
To reduce the run times, the unregulated auxiliary circulating pump in the generator circuit is only operated when the compressor is running and when there is a risk of frost. The uniform flow through the buffer tank connected in series extends the runtimes of the compressor and ensures the required heating water flow rate in all operating modes. Electrical connection cable EVL ..U between heat pump and heat pump manager must be ordered separately.

  • Weight: 651 kg
  • Connection voltage: 3/N/PE ~400 V, 50 Hz