LI 11TER+

Reversible air-to-water heat pump with waste heat recovery

No longer in the range since: 31.03.2011
Successor model / alternative: LAW 14ITR
LI 11/16TER+
LI 11/16TER+

Heat pump for heating and cooling for indoor installation with integrated WPM 2007 R controller. The control panel is integrated in a design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). The integrated air circuit enables corner or wall installation with air ducts at the air intake and the air outlet side. Sound-optimised through low-noise axial fan and vibration-isolated compressor. High coefficients of performance (COP) using an evaporator optimised for heating operation and energy-efficient defrosting by reverse circulation. Reversible refrigeration circuit with additional heat exchanger for higher domestic hot water temperatures in heating operation and waste heat recovery in cooling operation. Universal design with flexible expansion options for:

  • Bivalent operation (bivalent-renewable not possible)
  • Combined distribution systems for heating and cooling
  • Unmixed and mixed heating and cooling circuit
Silent cooling via panel heating/cooling systems requires the use of the room climate station (special accessory) to regulate the flow temperature on the basis of the air temperature and humidity of a reference room. Flow and return sensor integrated; external sensor (standard NTC-2) in the scope of supply.

Technical data

Reversible air-to-water heat pump with waste heat recovery
Order reference LI 11TER+
Casing colourWhite (similar to RAL 9003)
Heat output A-7/W35 / COP A-7/W35*6,6 kW / 2,7
Heat output A2/W35 / COP A2/W35*8,8 kW / 3,1
Heat output A7/W35 / COP A7/W35*11,3 kW / 3,6
Heat output A10/W35 / COP A10/W35*12,1 kW / 3,9
Nominal power consumption according to EN 14511 at A2/W352,86 kW
/ Amount of refrigerant / 5,1 kg
Dimensions (W x H x D)**0 x 0 x 0
Weight232 kg
Rated voltage3/N/PE ~400 V, 50 Hz
Starting current23 A
Fuse protection***C 16 A

**Please note that additional space is required for pipe connections, operation and maintenance.

***Die Absicherung ist als allpolige Trennvorrichtung auszuführen (gemeinsame Abschaltung aller Phasen)!

Documents and downloads

Data sheetProduct data sheet with system accessories» via e-mail
Instruction for useInstruction for use» via e-mail
Operating limits diagramOperating limits diagram» via e-mail
Declaration of conformityDeclaration of conformity» via e-mail