Heat pump for heating purposes for indoor installation with integrated WPM 2007 plus controller. The control panel is integrated into a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). The integrated air circuit enables corner or wall installation with air ducts at the air intake and the air outlet side. Sound-optimised through low-noise axial fan and vibration-isolated compressor. High coefficients of performance (COP) using an evaporator optimised for heating operation and energy-efficient defrosting by reverse circulation. Universal design with low temperature and high temperature levels, optional domestic hot water preparation and the possibility of flexible expansion for:
Information on leak tests and refrigerant quantities can be found here.
| High temperature air-to-water heat pump (High temperature) | ||
|---|---|---|
| Order reference | LIH 26TE | |
| Casing colour | White (similar to RAL 9003) | |
| Max. flow temperature | 75 °C | |
| Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) | -25 to 35 °C | |
| Heat output with 1 compressor / COP A7/W35* | 12,9 kW / 2,6 | |
| Heat output 1 compressor / COP A2/W35* | 15,7 kW / 3 | |
| Heat output with 1 compressor / COP A7/W35* | 19,5 kW / 3,6 | |
| Heat output with 1 compressor / COP A10/W35* | 20,2 kW / 3,7 | |
| Heat output with 2 compressor / COP A7/W45 | 15,2 kW / 2,2 | |
| Nominal power consumption according to EN 14511 at A2/W35 | 5,16 kW | |
| Sound power level device | 62 dB (A) | |
| Sound pressure level in 1 m (indoors) | 58 dB (A) | |
| Refrigerant / Amount of refrigerant | R404A / 3,7 kg | |
| Max. heating water flow rate / Pressure drop | 2,7 m³/h / 8200 Pa | |
| Heat source flow (min.) | 8000 m³/h | |
| Dimensions (W x H x D)** | 750 x 1710 x 1030 mm | |
| Weight | 377 kg | |
| Connection voltage | 3/N/PE ~400 V, 50 Hz | |
| Starting current with soft starter | 30 A | |
| Fuse protection | C 25 A | |
| Type of defrosting | Reverse circulation | |
| Connection heating | 1 ¼ inch | |
*Heat output and COP according to EN 14511 at A2/W35 (A2 = air intake temp. +2 °C, W35 = heating water outlet temp. +35 °C)
**Please note that additional space is required for pipe connections, operation and maintenance.
Product data sheet with system accessories:
as PDF 
by e-mail
Instruction for use:
as PDF
Equipment data:
as PDF
Declaration of conformity:
as PDF