HPL 9S-TUW

High efficiency air-to-water heat pump for outdoor installation incl. domestic hot water preparation.

HPL ...S-TUW
HPL ...S-TUW
  SG Ready

Heating package consisting of a high efficiency air-to-water heat pump for outdoor installation and Hydro-tower with integrated heat pump manager.

Heat pump

  • Simple hydraulic connection via the flexible connection kit (VS 32-220) provided
  • Extremely quiet thanks to sound-optimised casing and sound-insulated compressor housing
  • High efficiency thanks to high-performance evaporator, EC fan and COP booster
  • Integration of intelligent room temperature controllers (Smart RTC) enables a further increase in system efficiency
  • Flexible expansion options via 2 mixer outputs for bivalent operation and/or the control of mixed heating circuits

Hydro-tower

  • Minimal installation effort thanks to the space-optimised combination of buffer tank and domestic hot water cylinder
  • Simple commissioning with integrated heat pump manager and optimally coordinated hydraulic components
  • Demand-based supplementary heating via switchable pipe heater (2/4/6 kW)

HWK 332 Econ

Hydro Tower with WPM EconPlus

The Hydro-tower with integrated heat pump manager enables fast and simple connection of a high-efficiency air-to-water heat pump installed outdoors to a heating system with an unmixed heating circuit. The following components are mounted in a space-saving way and wired ready to use:

  • Switchable pipe heater (2/4/6 kW) for support for space heating
  • Buffer tank (100 l) with installation option for an additional immersion heater (up to CTHK 634)
  • Domestic hot water cylinder 300 l with 3.2 m² tube heat exchanger and 1.5 kW flange heater for thermal disinfection
  • Electronically regulated circulating pump wired ready to use for unmixed heating circuits (consumer circuit)
  • Auxiliary circulating pump for generator circuit and domestic hot water circulating pump
  • The hydraulic isolation of the generator circuit and the consumer circuit is carried out via two differential pressureless manifolds (bypass pipes), which are each fitted with a check valve.
To reduce the runtimes, the unregulated auxiliary circulating pump in the generator circuit is only operated when the compressor is running and when there is a risk of frost. The uniform flow through the buffer tank connected in series extends the runtimes of the compressor and ensures the required heating water flow rate in all operating modes. Access for service work from the front, no minimum clearances required on the sides. Left and right-side wall installation is possible.

 

Technical data

High efficiency air-to-water heat pump for outdoor installation incl. domestic hot water preparation.
Order reference HPL 9S-TUW
Heat pump code5011
Casing colourlight grey
Max. flow temperature60 °C
Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation)-22 to 35 °C
Heat output A-7/W35 / COP A-7/W35*5,5 kW / 3,3
Heat output max. A-7/W35 / COP A-7/W35*5,5 kW / 3,3
Heat output A2/W35 / COP A2/W35*7,2 kW / 4,3
Heat output max. A2/W35 / COP A2/W35*7,2 kW / 4,3
Heat output A7/W35 / COP A7/W35*8,4 kW / 4,9
Heat output max. A7/W35 / COP A7/W35*8,4 kW / 4,9
Heat output A10/W35 / COP A10/W35*8,9 kW / 5,3
Heat output max. A10/W35 / COP A10/W35*8,9 kW / 5,3
Nominal power consumption according to EN 14511 at A2/W351,7 kW
Nominal power consumption according to EN 14511 at A7/W351,71 kW
Sound power level53 dB (A)
Sound pressure level in 10 m25 dB (A)
Refrigerant / Amount of refrigerantR410A / 3,4 kg
Max. heating water flow rate / Pressure drop1,5 m³/h / 9700 Pa
Heat source flow (min.)2500 m³/h
Dimensions (W x H x D)**0 x 0 x 0
Rated voltage3/N/PE ~400 V, 50 Hz
Starting current17 A
Fuse protection***C 10 A
Type of defrostingReverse circulation
Connection heating1 ¼ inch

*Heat output and coefficient of performance (COP) according to EN 14511

**Please note that additional space is required for pipe connections, operation and maintenance.

***Die Absicherung ist als allpolige Trennvorrichtung auszuführen (gemeinsame Abschaltung aller Phasen)!

Documents and downloads

Data sheetProduct data sheet with system accessories» via e-mail
Product informationProduct information» via e-mail
Operating limits diagramOperating limits diagram» via e-mail
Declaration of conformityDeclaration of conformity» via e-mail