Dimplex / Products / Heat pumps / Air-to-Water /
|
LA 11ASR |
Air-to-water heat pump for outdoor installation with external temperature controlled WPM 2006 R heat pump manager and reversible refrigeration circuit for heating and cooling. Sound-optimised through the use of low-noise crescent wing axial fans and deflector hoods. Energy-efficient defrosting by reverse circulation und diagonally positioned evaporator. Universal design with optional domestic hot water preparation and flexible expansion possibilities for:
Information on leak tests and refrigerant quantities can be found here.
| Reversible air-to-water heat pump with additional heat exchanger (Low temperature) | ||
|---|---|---|
| Order reference | LA 11ASR | |
| Casing colour | White aluminium (similar to RAL 9006) | |
| Max. flow temperature | 58 °C | |
| Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) | -25 to 35 °C | |
| Lower operating limit heat source (cooling operation) / Upper operating limit heat source (cooling operation) | 15 to 40 °C | |
| Standard temperature spread heating EN 14511 | 5,0 K | |
| Heat output 1 compressor / COP A2/W35* | 8,8 kW / 3,1 | |
| Heat output with 1 compressor / COP A7/W35* | 11,3 kW / 3,6 | |
| Standard temperature spread cooling EN 14511 | 5,0 K | |
| Cooling capacity 1 compressor / COP A35/W7* | 7,5 kW / 2,1 | |
| Nominal power consumption according to EN 14511 at A2/W35 | 2,9 kW | |
| Sound power level device | 63 dB (A) | |
| Sound pressure level in 10 m | 33 dB (A) | |
| Refrigerant / Amount of refrigerant | R404A / 5,1 kg | |
| Heat source flow (min.) | 2500 m³/h | |
| Max. heating water flow rate / Pressure drop | 1,3 m³/h / 10900 Pa | |
| Dimensions (W x H x D)** | 1360 x 1360 x 850 mm | |
| Weight | 241 kg | |
| Connection voltage | 3/N/PE ~400 V, 50 Hz | |
| Starting current with soft starter | 23 A | |
| Fuse protection | C 16 A | |
| Type of defrosting | Reverse circulation | |
| Connection heating | 1 inch | |
*Heat output and COP according to EN 14511 at A2/W35 (A2 = air intake temp. +2 °C, W35 = heating water outlet temp. +35 °C)
**Please note that additional space is required for pipe connections, operation and maintenance.
Product data sheet with system accessories:
as PDF 
by e-mail
Instruction for use:
as PDF
Product information:
as PDF
Equipment data:
as PDF
Declaration of conformity:
as PDF