Press Trade Fair Newsletter Sitemap Search:

Dimplex / Products / Heat pumps / Air-to-Water / Outdoor installation

LA 6TU

High-efficiency air-to-water heat pump for installation close to walls

LA 6TU
LA 6TU

The new LA 6TU high-efficiency air-to-water heat pump stands out thanks to its high coefficients of performance (COPs), even at low heat outputs. This makes it perfect for low-energy houses. High performance factors are achieved with an electronically controlled expansion valve and a slow-running owl's wing EC fan - and high performance factors translate into low operating costs. The special casing design makes installation close to walls possible, thus saving space in the garden. The heat pump can be combined with a hydro tower with an integrated domestic hot water cylinder for quick and easy installation.

The benefits at a glance:

  • Particularly quiet thanks to an owl's wing EC fan, which has a naturally low air noise level
  • Electronic expansion valve for high seasonal performance factors and low operating costs
  • Minimal space requirements through installation close to walls and compact dimensions - minimum distance from wall on air intake side: 50 cm
  • WPM EconPlus heat pump manager with integrated thermal energy metering and flow switch for high operational safety
  • Combination with the hydro tower for quick and easy installation with minimal space requirements

Information on leak tests and refrigerant quantities can be found here.

Seal of approval EHPA

European Heat Pump Association - EHPA
 

Technical data

High-efficiency air-to-water heat pump for installation close to walls (Low temperature)
Order reference LA 6TU
Casing colourWhite aluminium (similar to RAL 9006)
Max. flow temperature60 °C
Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation)-20 to 35 °C
Heat output with 1 compressor / COP A7/W35*4 kW / 2,9
Heat output 1 compressor / COP A2/W35*5,1 kW / 3,8
Heat output with 1 compressor / COP A7/W35*6,4 kW / 4,6
Heat output with 1 compressor / COP A10/W35*6,7 kW / 4,7
Nominal power consumption according to EN 14511 at A2/W351,3 kW
Sound power level device58 dB (A)
Sound pressure level in 10 m29 dB (A)
Refrigerant / Amount of refrigerantR410A / 3,4 kg
Max. heating water flow rate / Pressure drop1,1 m³/h / 9500 Pa
Heat source flow (min.)2700 m³/h
Dimensions (W x H x D)**1350 x 940 x 600 mm
Weight165 kg
Connection voltage3/N/PE ~400 V, 50 Hz
Starting current with soft starter27 A
Fuse protectionC 16 A
Type of defrostingReverse circulation
Connection heating1 inch
Seal of approval EHPA (valid until)Yes / 12.12.2014

*Heat output and COP according to EN 14511 at A2/W35 (A2 = air intake temp. +2 °C, W35 = heating water outlet temp. +35 °C)

**Please note that additional space is required for pipe connections, operation and maintenance.