Press Trade Fair Newsletter Sitemap Search:

Dimplex / Products / Heat pumps / Air-to-Water / Outdoor installation

LA 9TU

High-efficiency air-to-water heat pump for universal outdoor installation

LA 9TU
LA 9TU

Heat pump for heating purposes for outdoor installation with wall-mounted WPM EconPlus heat pump manager. Sound-optimised through the use of slow-running 'owl's wing' ventilators with a low natural sounding noise, an encapsulated compressor housing with free-swinging compressor baseplate for solid-borne sound insulation. High coefficients of performance (COP) through high-performance evaporator and compliance with the requirements of EN 14511 for larger volume flows on the heat consumption side. High operational safety through sensor monitoring of the refrigeration circuit for energy-efficient defrosting; integrated thermal energy metering (display of the thermal energy volume for heating and domestic hot water preparation on the WPM EconPlus heat pump manager). Access for service work on the outlet side; the minimum clearances must be observed for installation close to walls. Universal design with flexible expansion options for:

  • Bivalent or bivalent-renewable operating mode
  • Distribution systems with unmixed and mixed heating circuits
Soft starter, integrated flow and return sensors; external sensor (standard NTC-2) included in the scope of supply. Electrical connection cable EVL ..U between heat pump and heat pump manager must be ordered separately.

Information on leak tests and refrigerant quantities can be found here.

Seal of approval EHPA

European Heat Pump Association - EHPA
 

Technical data

High-efficiency air-to-water heat pump for universal outdoor installation (Low temperature)
Order reference LA 9TU
Casing colourWhite aluminium (similar to RAL 9006)
Max. flow temperature58 °C
Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation)-20 to 35 °C
Heat output with 1 compressor / COP A7/W35*5,2 kW / 2,8
Heat output 1 compressor / COP A2/W35*7,5 kW / 3,7
Heat output with 1 compressor / COP A7/W35*9,2 kW / 4,2
Heat output with 1 compressor / COP A10/W35*10,2 kW / 4,5
Nominal power consumption according to EN 14511 at A2/W352 kW
Sound power level device60 dB (A)
Sound pressure level in 10 m30 dB (A)
Refrigerant / Amount of refrigerantR404A / 3,4 kg
Max. heating water flow rate / Pressure drop1,6 m³/h / 7300 Pa
Heat source flow (min.)2500 m³/h
Dimensions (W x H x D)**910 x 1460 x 750 mm
Weight208 kg
Connection voltage3/N/PE ~400 V, 50 Hz
Starting current with soft starter17 A
Fuse protectionC 16 A
Type of defrostingReverse circulation
Connection heating1 ¼ inch
Seal of approval EHPA (valid until)Yes / 08.11.2013

*Heat output and COP according to EN 14511 at A2/W35 (A2 = air intake temp. +2 °C, W35 = heating water outlet temp. +35 °C)

**Please note that additional space is required for pipe connections, operation and maintenance.

Product data sheet with system accessories: Data sheet as PDF Data sheet by e-mail

Instruction for use: Instruction for use as PDF

Product information: Product information as PDF

Equipment data: Equipment data as PDF

Declaration of conformity: Declaration of conformity as PDF