Dimplex / Products / Heat pumps / Brine-to-Water /
|
HPK ..TEW |
Consists of compact brine-to-water heat pump, WWSP 229E built-under domestic hot water cylinder and connection kit for quick and easy connection of the individual components to the heating system.
Compact brine-to-water heat pump
Heat pump for heating purposes for indoor installation with integrated WPM EconPlus. Sound-optimised through insulated metal casing and double vibration-isolated compressor. Integrated solid-borne sound insulation for direct connection to the heating system. Economiser for high coefficients of performance (COP). Sensor monitoring of the refrigeration circuit for a high degree of operational safety and integrated thermal energy metering (display of the calculated quantity of thermal energy for heating and domestic hot water preparation on the WPM EconPlus heat pump manager). The control panel is integrated into a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). Compact design with domestic hot water preparation and integrated components for direct connection of an unmixed heating circuit (must not be used for bivalent systems):
Information on leak tests and refrigerant quantities can be found here.
| SIK 11TE-2 heating and domestic hot water preparation package (Low temperature) | ||
|---|---|---|
| Order reference | HPK 11TEW | |
| Casing colour | White (similar to RAL 9003) | |
| Max. flow temperature | 58 °C | |
| Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) | -5 to 25 °C | |
| Heat output 1 compressor at B5/W35 / COP at B0/W35* | 11,7 kW / 4,2 | |
| Heat output with 1 compressor / COP at B0/W45 | 11,2 kW / 3,2 | |
| Nominal power consumption according to EN 14511 at B0/W35 | 2,79 kW | |
| Sound power level device | 51 dB (A) | |
| Refrigerant / Amount of refrigerant | R407C / 2 kg | |
| Max. heating water flow rate / Pressure drop | 2 m³/h / 15000 Pa | |
| Heat source flow (min.) | 3 m³/h | |
| Dimensions (W x H x D)** | 650 x 2150 x 690 mm | |
| Weight | 301 kg | |
| Connection voltage | 3/N/PE ~400 V, 50 Hz | |
| Starting current with soft starter | 19 A | |
| Fuse protection | C 20 A | |
| Connection heating | 1 ¼ inch | |
| Heat source connection | 1 ¼ inch | |
*Heat output and coefficient of performance (COP) according to EN 14511 at B0/W35 (B0 = brine inlet temp. 0 ℃, W35 = heating water outlet temp. +35 °C)
**Please note that additional space is required for pipe connections, operation and maintenance.