Press Trade Fair Newsletter Sitemap Search:

Dimplex / Products / Heat pumps / Brine-to-Water / Universal for customer-specific versions

SI 9ME

Brine-to-water heat pump

SI 9ME
SI 9ME

Heat pump for heating purposes for indoor installation with integrated WPM 2007 plus controller. The control panel is integrated into a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). Variable connection options for brine and heating connections on the back board of the casing. Sound-optimised through insulated metal casing and double vibration-isolated compressor. Economiser for high coefficients of performance (COP). Universal design with optional domestic hot water preparation and flexible expansion possibilities for:

  • Bivalent or bivalent-renewable operating mode
  • Distribution systems with unmixed and mixed heating circuits
Integrated soft starter and load contactor for brine circulating pump, integrated flow and return sensors; external sensor (standard NTC-2) and dirt filter for brine circuit included in the scope of supply.

Information on leak tests and refrigerant quantities can be found here.

Seal of approval NF-PAC

NF-PAC
 

Technical data

Brine-to-water heat pump (Low temperature)
Order reference SI 9ME
Casing colourWhite (similar to RAL 9003)
Max. flow temperature58 °C
Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation)-5 to 25 °C
Heat output 1 compressor at B5/W35 / COP at B0/W35*8,9 kW / 4
Heat output with 1 compressor / COP at B0/W458,7 kW / 3,1
Nominal power consumption according to EN 14511 at B0/W352,22 kW
Sound power level device51 dB (A)
Refrigerant / Amount of refrigerantR407C / 1,7 kg
Max. heating water flow rate / Pressure drop1,5 m³/h / 9200 Pa
Heat source flow (min.)2 m³/h
Dimensions (W x H x D)**650 x 805 x 462 mm
Weight118 kg
Connection voltage1/N/PE ~230 V, 50 Hz
Starting current with soft starter38 A
Fuse protectionC 20 A
Connection heating1 ¼ inch
Heat source connection1 ¼ inch
Seal of approval NF-PAC (valid until)Yes / 30.06.2013

*Heat output and coefficient of performance (COP) according to EN 14511 at B0/W35 (B0 = brine inlet temp. 0 ℃, W35 = heating water outlet temp. +35 °C)

**Please note that additional space is required for pipe connections, operation and maintenance.

Product data sheet with system accessories: Data sheet as PDF Data sheet by e-mail

Instruction for use: Instruction for use as PDF

Equipment data: Equipment data as PDF

Declaration of conformity: Declaration of conformity as PDF