A pipe duct system with integrated bypass flaps enables variable use of the heat extracted from outdoor or indoor air for hot water preparation. (lower operating limit of the HP: + 8 °C)

Indoor air is removed by suction from storage rooms or wine cellars, and is then cooled and dehumidified in the hot water heat pump and blown out again.
Suitable locations for installation include hobby rooms, furnace rooms and laundry rooms. The air ducting in the heated section of the system should be insulated with water-proof insulation to prevent the formation of condensate.

Dehumidified air in laundry rooms can be used to dry laundry and prevents damage caused by high humidity.

Our standard heat exchanger for hot water heat pumps additionally enables direct connection of a second heat generator, e.g. a solar energy system or a boiler.