Dimplex / Products / Heat pumps / Special accessories
Order reference: WWSP 332
Nominal content 300l, usable capacity 277l, heat exchanger area 3.2 m smooth pipe (internal) for a transmission capacity up to 16 kW, 3 supporting feet, steel cylinder (special inside enamelling) with protection anode, max. operating pressure 10 bar, polyurethane insulation for minimal stand-by losses (approx. 2.4 kWh/24h), 1" external thread drinking water connection, 3/4" circulation, integrated temperature sensor for connection to the heat pump manager, colour white.
Order reference: WWSP 880
Nominal content 400 l, usable capacity 350 l, heat exchanger area 4.2 m smooth pipe (internal) for a transmission capacity up to 20 kW, 3 supporting feet, steel cylinder (special inside enamelling) with protection anode, max. operating pressure 10 bar, polyurethane insulation for minimal stand-by losses (approx. 2.8 kWh/24h), 1" external thread drinking water connection, 3/4" circulation, integrated temperature sensor for connection to the heat pump manager, colour white.
Order reference: WWSP 900
Nominal content 500 l, usable capacity 430 l, heat exchanger area 5.7 m² for a transmission capacity up to approx. 30 kW, stand-by loss approx. 3.3 kWh/24h
Order reference: WWSP 885S
800-litre cylinder for universal use, for domestic water heating, steel (special inside enamelling according to DIN 4753, primer-coated on the outside) with 3 tube heat exchangers (internal). 2 tube heat exchangers at the top (internal and external), each with 3 m2 heat exchanger area (parallel connection via T-joint; lower tube heat exchanger (2.0 m2)can be used individually for domestic water heating or as a solar heat exchanger. Magnesium protection anode, 1 1/4", for supplementary cathode corrosion protection, temperature sensor (variable positioning via sensor terminal strips (NTC-2M and NTC 10M temperature sensors for connection to the heat pump manager included in the scope of supply); installation of TK150/DN 110 flange heater possible, hydraulic connection 1 ½", flow/return 1", circulation ¾" (all connections flat-sealing with external thread); diameter without insulation 795 mm; tilting dimension 1950 mm; separate custom-fitted 2-part polyester mat thermal insulation (100 mm thickness) with polyester outer surface including base insulation for minimal heat downtime losses included in the scope of supply, fire protection class B2, colour white aluminium (RAL 9006).
Order reference: WWSP 432 SOL
Solar domestic hot water cylinder made of steel (special enamelling inside) with protection anode, two internal bare-tube heat exchangers for solar and heating, thermometer, polyurethane insulation for minimal stand-by losses, colour white, TK150/DN110 flange. Suitable for heat pump operation.
Order reference: WWSP 540 SOL
Solar domestic hot water cylinder made of steel (special enamelling inside) with protection anode, two internal bare-tube heat exchangers for solar and heating, thermometer, polyurethane insulation for minimal stand-by losses, colour white, TK150/DN110 flange. Suitable for heat pump operation.
Order reference: WWSP 442E
Capacity 400 l; in brine-to-water heat pump design, usable capacity 350 l, heat exchanger area 4.2 m² smooth pipe (internal),
three supporting feet, steel cylinder (special inside enamelling)
with protection anode, max. operating pressure 10 bar, 1¼" heating water connections, 1" external thread drinking water connections, circulation ¾" internal , polyurethane insulation with minimal stand-by losses (approx. 2.7 kW/24h); integrated temperature sensor for connection
to the heat pump manager, casing colour: white; brown red design screen.
Order reference: WWSP 229E
Nominal capacity 227 l, in brine-to-water heat pump design to enable space-saving installation on the built-under buffer, tube heat exchanger (internal), steel cylinder (special inside enamelling) with protection anode, polyurethane insulation with minimum stand-by losses; integrated temperature sensor for connection to the heat pump manager, colour: white, brown red design screen
Order reference: FLH 25M
For reheating and thermal disinfection; FLH 25M flange heater, 2.5 kW, 230 V~; temperature controller adjustable from 15°C to 85°C; safety temperature limiter, suitable for all hot water cylinders (WWSP), installation depth 450 mm.
Order reference: FLHU 70
with temperature controller, adjustable from 15°C to 85°C; safety temperature limiter, suitable for all hot water cylinders (WWSP) with switchable outputs of 2.0 kW, 2.7 kW and 4.0 kW. Connection voltage: 3/N/PE~400V, 50 Hz.
Order reference: FLH 60
with temperature controller, adjustable from 15°C to 85°C; safety temperature limiter, suitable for all hot water cylinders (WWSP) with an output of 6 kW. Connection voltage: 3/N/PE~400V, 50 Hz.
Order reference: SVK 852
For the cold water connection of drinking water cylinders to the supply network according to DIN 1988; connection 1" external thread.
Order reference: KRRV 003
Capillary tube controller setting range: 0 - 70 °C switching capacity at 230 V, 50 Hz, 10 A switching temperature difference: 1.0 - 2.0 K, sheath tube length: 200 mm.