Order reference: WWM 25
Combinable module with insulation jackets for connecting DHW or swimming pool water preparation. Can be used for a heating water flow rate of up to 2.5 m³/h. Consisting of two ball valves with check valve, two integrated thermometers, pump ball valve, insulation jackets, installation option for circulating pump, inside micrometer 180 mm, DN 25, which is to be constructed after pressure loss of the heating system (not included in the scope of supply).
Order reference: MMH 25
Combinable module with insulation jackets for connecting a mixed heating circuit. Can be used for a heating water flow rate of up to 2 m³/h. Consisting of two ball valves with check valve, two thermometers, 3-way mixer with actuator and 140 sec. runtime, connection voltage ~230 V, degree of protection IP40, strap-on sensor and insulation jackets, installation option for regulated circulating pump, inside micrometer 180 mm, DN 25, which is to be constructed after pressure loss of the heating system (pump not included in the scope of supply).
Order reference: VTB 25
Combinable module with insulation jackets for simultaneous connection of several heating distribution system modules, with two 1 ½" (external/internal thread) connecting pairs each to the top and bottom, universally combinable with KPV 25, MMH 25 and WWM 25, complete with union and connecting pieces (flat sealing).
Order reference: UPE 60
Electronically-controlled heat circulating pump with integrated flexible capacity via freely-adjustable rotational speed, micrometer 180 mm, low energy consumption thanks to energy efficiency class A (fulfils the requirements of EnEV, §14 (3)), automatic lowering of temperature at night, type of regulation (controlled or constant rotational speed) and the control curve can be set automatically via Softtouch, including pump plug for easy installation of the electrical connection cable.
Maximum delivery height 3.2 m at a volume flow of 2 m3/h
Order reference: UPE 70-25
High-efficiency wet running pump with integrated electronic power regulation. Types of regulation selectable via operating button for optimum load adjustment (differential pressure regulation constant (Δp-c) or variable (Δp-v) and speed adjustment via control input). Low energy consumption thanks to energy efficiency class A (complies with the requirements of the EnEV, §14 (3)), inside micrometer 180 mm, including mains and control cable (length 1.5 m). Maximum delivery height 5.9 m at a volume flow of 2 m3/h Relay for decoupling the control and load circuits, including relay base and retaining clip in the scope of supply.
Order reference: UPE 70-32
High-efficiency wet running pump with integrated electronic power regulation. Types of regulation selectable via operating button for optimum load adjustment (differential pressure regulation constant (Δp-c) or variable (Δp-v) and speed adjustment via control input). Low energy consumption thanks to energy efficiency class A (complies with the requirements of the EnEV, §14 (3)), inside micrometer 180 mm, including mains and control cable (length 1.5 m). Maximum delivery height 5.9 m at a volume flow of 2 m3/h Relay for decoupling the control and load circuits, including relay base and retaining clip in the scope of supply.
Order reference: UPE 80-25
High-efficiency wet running pump with integrated electronic power regulation. Types of regulation selectable via operating button for optimum load adjustment (differential pressure regulation constant (Δp-c) or variable (Δp-v) and speed adjustment via control input). Low energy consumption thanks to energy efficiency class A (complies with the requirements of the EnEV, §14 (3)), inside micrometer 180 mm, including mains and control cable (length 1.5 m). Maximum delivery height 5.2 m at a volume flow of 5 m3/h Relay for decoupling the control and load circuits, including relay base and retaining clip in the scope of supply.
Order reference: UPE 80-32
High-efficiency wet running pump with integrated electronic power regulation. Types of regulation selectable via operating button for optimum load adjustment (differential pressure regulation constant (Δp-c) or variable (Δp-v) and speed adjustment via control input). Low energy consumption thanks to energy efficiency class A (complies with the requirements of the EnEV, §14 (3)), inside micrometer 180 mm, including mains and control cable (length 1.5 m). Maximum delivery height 5.2 m at a volume flow of 5 m3/h Relay for decoupling the control and load circuits, including relay base and retaining clip in the scope of supply.
Order reference: UPE 120-32
High-efficiency wet running pump with integrated electronic power regulation. Types of regulation selectable via operating button for optimum load adjustment (differential pressure regulation constant (Δp-c) or variable (Δp-v) and speed adjustment via control input). Low energy consumption thanks to energy efficiency class A (complies with the requirements of the EnEV, §14 (3)), inside micrometer 180 mm, including mains and control cable (length 1.5 m). Maximum delivery height 8.5 m at a volume flow of 7 m3/h Relay for decoupling the control and load circuits, including relay base and retaining clip in the scope of supply.
Order reference: WWM 25
Combinable module with insulation jackets for connecting DHW or swimming pool water preparation. Can be used for a heating water flow rate of up to 2.5 m³/h. Consisting of two ball valves with check valve, two integrated thermometers, pump ball valve, insulation jackets, installation option for circulating pump, inside micrometer 180 mm, DN 25, which is to be constructed after pressure loss of the heating system (not included in the scope of supply).
Order reference: VTB 25
Combinable module with insulation jackets for simultaneous connection of several heating distribution system modules, with two 1 ½" (external/internal thread) connecting pairs each to the top and bottom, universally combinable with KPV 25, MMH 25 and WWM 25, complete with union and connecting pieces (flat sealing).
Order reference: WPG 25
Pump unit DN 25 for connecting the hot water cylinder directly to the KPV 25 and/or the DDV 32. Consisting of:
Order reference: WPG 32
Pump unit DN 32 for connecting the hot water cylinder directly to the KPV 25 and/or the DDV 32. Consisting of: 1 1/4" elbow union with manual air bleeds for hot water flow Installation option for DN 32 circulating pump with two ball valves and gravity control. 1 1/4" elbow union with drainage for hot water return.
Order reference: UP 60
Delivery height max. 3,5 m at a volume flow of 2 m³/h.
Order reference: UP 60-32
Delivery height max. 3,5 m at a volume flow of 2 m³/h.
Order reference: UP 80
Delivery height max. 4 m at a volume flow of 5 m³/h.
Order reference: MMB 25
Combinable mixer module for connecting a second heat generator (e.g. oil boiler) or a renewable heat generator with heat accumulator. Can be used for a heating water flow rate of up to 2 m³/h. Consisting of a 4-way mixer with actuator and 140 sec. runtime, connection voltage ~230 V, degree of protection IP40.
Order reference: SST 25
Heat exchanger solar station consisting of solar separation system and pump assembly with insulation jackets for integrating solar installations up to 10 m² into the DHW heating system. The solar station enables efficient hot water heating via the heat pump as well as via the solar installation. Modules with primary and secondary cycle consisting of: 2 circulating pumps (WILO- STAR-ST 25/6 and STAR-RS 24/4); 4 ball valves 1" with thermometer, return flow inhibitor, safety assembly with safety valve and 0-10 bar pressure gauge, connection options for expansion vessel (solar controller not included in scope of supply).
Order reference: WWM 50
Combinable module (DN 50) with insulation jackets for connection of an unmixed heating circuit or domestic hot water or swimming pool water preparation system. Can be used for a heating water flow of up to 7.5 m³/h. Consisting of two ball valves with check valve, 2 integrated thermometers, pump ball valve, insulation jackets, installation option for a circulating pump (nominal width DN 32 - inner micrometer 180 mm; pump not included in the scope of supply).
Order reference: SMF 25
Dirt trap for installation in the heating circuit, mesh size 0.6 mm, suitable for all non-corrosive substances up to 150°C. Pipework is kept free from hazardous impurities, the heat pump evaporator is thereby protected from damage and the service life is raised for the regulating devices and valves.
Order reference: SMF 32
Dirt trap for installation in the heating circuit, mesh size 0.6 mm, suitable for all non-corrosive substances up to 150°C. Pipework is kept free from hazardous impurities, the heat pump evaporator is thereby protected from damage and the service life is raised for the regulating devices and valves.
Order reference: SMF 40
Dirt trap for installation in the heating circuit, mesh size 0.6 mm, suitable for all non-corrosive substances up to 150°C. Pipework is kept free from hazardous impurities, the heat pump evaporator is thereby protected from damage and the service life is raised for the regulating devices and valves.
Order reference: SMF 50
Dirt trap for installation in the heating circuit, mesh size 0.6 mm, suitable for all non-corrosive substances up to 150°C. Pipework is kept free from hazardous impurities, the heat pump evaporator is thereby protected from damage and the service life is raised for the regulating devices and valves.
Order reference: SMF 65
Dirt trap for installation in the heating circuit, mesh size 0.6 mm, suitable for all non-corrosive substances up to 150°C. Pipework is kept free from hazardous impurities, the heat pump evaporator is thereby protected from damage and the service life is raised for the regulating devices and valves.
Order reference: KOMP 25
Double-sphere rubber expansion joint for isolating heat pumps and heating systems. Absorbs oscillations and movements caused by pumps, compressors, fittings and other sources, reduces noise output and evens out internal strain (axial and lateral deviations) stemming from imprecisions in assembly. EPDM bellows, galvanised C-steel internal thread connections, service temperature -10°C to 110°C. 22 mm compression (stroke 10 / -12), 6 mm dilatation, 22 mm lateral movement, 45° angled stroke. Horizontal installation as close as possible to the heat pump is recommended!
Order reference: KOMP 32
Double-sphere rubber expansion joint for isolating heat pumps and heating systems. Absorbs oscillations and movements caused by pumps, compressors, fittings and other sources, reduces noise output and evens out internal strain (axial and lateral deviations) stemming from imprecisions in assembly. EPDM bellows, galvanised C-steel internal thread connections, service temperature -10°C to 110°C. 22 mm compression (stroke 10 / -12), 6 mm dilatation, 22 mm lateral movement, 45° angled stroke. Horizontal installation as close as possible to the heat pump is recommended!
Order reference: KOMP 40
Double-sphere rubber expansion joint for isolating heat pumps and heating systems. Absorbs oscillations and movements caused by pumps, compressors, fittings and other sources, reduces noise output and evens out internal strain (axial and lateral deviations) stemming from imprecisions in assembly. EPDM bellows, galvanised C-steel internal thread connections, service temperature -10°C to 110°C. 22 mm compression (stroke 10 / -12), 6 mm dilatation, 22 mm lateral movement, 45° angled stroke. Horizontal installation as close as possible to the heat pump is recommended!
Order reference: KOMP 50
Double-sphere rubber expansion joint for isolating heat pumps and heating systems. Absorbs oscillations and movements caused by pumps, compressors, fittings and other sources, reduces noise output and evens out internal strain (axial and lateral deviations) stemming from imprecisions in assembly. EPDM bellows, galvanised C-steel internal thread connections, service temperature -10°C to 110°C. 22 mm compression (stroke 10 / -12), 6 mm dilatation, 22 mm lateral movement, 45° angled stroke. Horizontal installation as close as possible to the heat pump is recommended!
Order reference: VSE 32-50
Ready-for-use DN 32 stainless steel Wellflex pipe with insulation, 1 1/2" cap nut and transitional screw connection to 1 1/4" external thread for quick and easy hydraulic integration of the heat pump into the heat distribution system.
Order reference: VSE 32-100
Ready-for-use DN 32 stainless steel Wellflex pipe with insulation, 1 1/2" cap nut and transitional screw connection to 1 1/4" external thread for quick and easy hydraulic integration of the heat pump into the heat distribution system.
Order reference: VSE 32-150
Ready-for-use DN 32 stainless steel Wellflex pipe with insulation, 1 1/2" cap nut and transitional screw connection to 1 1/4" external thread for quick and easy hydraulic integration of the heat pump into the heat distribution system.
Order reference: VSE 32-200
Ready-for-use DN 32 stainless steel Wellflex pipe with insulation, 1 1/2" cap nut and transitional screw connection to 1 1/4" external thread for quick and easy hydraulic integration of the heat pump into the heat distribution system.
Order reference: VSE 32-300